Current<Ppdu>

RepCap Settings

# Range: Nr1 .. Nr100
rc = driver.uwbMeas.multiEval.modulation.current.repcap_ppdu_get()
driver.uwbMeas.multiEval.modulation.current.repcap_ppdu_set(repcap.Ppdu.Nr1)

SCPI Commands :

FETCh:UWB:MEASurement<Instance>:MEValuation:MODulation:CURRent<PPDU>
READ:UWB:MEASurement<Instance>:MEValuation:MODulation:CURRent<PPDU>
class CurrentCls[source]

Current commands group definition. 2 total commands, 0 Subgroups, 2 group commands Repeated Capability: Ppdu, default value after init: Ppdu.Nr1

class ResultData[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Freq_Offset_Hz: float: No parameter help available

  • Freq_Offset: float: No parameter help available

  • Chip_Clock_Error: float: No parameter help available

  • Pulse_Nsme: float: No parameter help available

  • Sym_Mod_Accuracy: float: No parameter help available

  • Side_Lobe_Peak: float: No parameter help available

  • Pulse_Ml_Width: float: No parameter help available

  • Sym_Time_Jitter: float: No parameter help available

  • Sym_Phase_Jitter: float: No parameter help available

  • Chip_Time_Jitter: float: No parameter help available

  • Chip_Phase_Jitter: float: No parameter help available

  • Symbol_Evm: float: No parameter help available

  • Chip_Evm: float: No parameter help available

  • Rmarker: float: RMARKER time

  • Shr_Nrmse: float: NRMSE for SHR

  • Phr_Nrmse: float: NRMSE for PHR

  • Psdu_Nrmse: float: NRMSE for PSDU

  • Sts_Nrmse: float: NRMSE for STS

  • Sync_Pulse_Loc_Pol: enums.Result: No parameter help available

  • Sfd_Pulse_Loc_Pol: enums.Result: No parameter help available

  • Sts_Pulse_Loc_Pol: enums.Result: No parameter help available

  • Iq_Offset: float: I/Q offset

fetch(ppdu=Ppdu.Default) ResultData[source]
# SCPI: FETCh:UWB:MEASurement<Instance>:MEValuation:MODulation:CURRent<PPDU>
value: ResultData = driver.uwbMeas.multiEval.modulation.current.fetch(ppdu = repcap.Ppdu.Default)

Return the current, average, extreme and standard deviation single value modulation results.

param ppdu:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Current’)

return:

structure: for return value, see the help for ResultData structure arguments.

read(ppdu=Ppdu.Default) ResultData[source]
# SCPI: READ:UWB:MEASurement<Instance>:MEValuation:MODulation:CURRent<PPDU>
value: ResultData = driver.uwbMeas.multiEval.modulation.current.read(ppdu = repcap.Ppdu.Default)

Return the current, average, extreme and standard deviation single value modulation results.

param ppdu:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Current’)

return:

structure: for return value, see the help for ResultData structure arguments.

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.uwbMeas.multiEval.modulation.current.clone()