Current<Ppdu>

RepCap Settings

# Range: Nr1 .. Nr100
rc = driver.uwbMeas.multiEval.pmask.margin.area.current.repcap_ppdu_get()
driver.uwbMeas.multiEval.pmask.margin.area.current.repcap_ppdu_set(repcap.Ppdu.Nr1)

SCPI Command :

CALCulate:UWB:MEASurement<Instance>:MEValuation:PMASk:MARGin:AREA<nr>:CURRent<PPDU>
class CurrentCls[source]

Current commands group definition. 1 total commands, 0 Subgroups, 1 group commands Repeated Capability: Ppdu, default value after init: Ppdu.Nr1

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Margin_Upper_Y: enums.ResultStatus2: Limit check result for upper area no.

  • Margin_Lower_Y: enums.ResultStatus2: Limit check result for lower area no.

calculate(area=Area.Default, ppdu=Ppdu.Default) CalculateStruct[source]
# SCPI: CALCulate:UWB:MEASurement<Instance>:MEValuation:PMASk:MARGin:AREA<nr>:CURRent<PPDU>
value: CalculateStruct = driver.uwbMeas.multiEval.pmask.margin.area.current.calculate(area = repcap.Area.Default, ppdu = repcap.Ppdu.Default)

Returns the limit check results for the pulse mask measurement, for the pulse mask area <no>. See also ‘Pulse Mask square’.

param area:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Area’)

param ppdu:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Current’)

return:

structure: for return value, see the help for CalculateStruct structure arguments.

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.uwbMeas.multiEval.pmask.margin.area.current.clone()